Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 926
Filtrar
3.
J Chin Med Assoc ; 87(4): 377-383, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38335460

RESUMO

BACKGROUND: Device-assisted enteroscopy has been used for over 20 years for the management of patients with suspected small bowel bleeding. Unlike esophagogastroduodenoscopy and colonoscopy, the appropriate timing of enteroscopy is still unknown. In recent guidelines, early enteroscopy is suggested to maximize diagnostic yield and therapeutic yield in patients with suspected small bowel bleeding. However, few studies have identified its influence on clinical outcomes, including mortality or rebleeding rate. We conducted this study to evaluate the influence of the timing of double-balloon enteroscopy on clinical outcomes in patients with suspected small bowel bleeding. METHODS: Patients with overt small bowel bleeding who underwent double-balloon enteroscopy from January 2013 to February 2021 were retrospectively reviewed. Patients were categorized into an early enteroscopy group (≤14 days) and a nonearly enteroscopy group (>14 days). Clinical outcomes, including short-term mortality and rebleeding rate, long-term mortality and rebleeding rate, diagnostic yield, and therapeutic yield, were analyzed. RESULTS: A total of 100 patients (mean age, 66.2 years; 53% male) were included, and 44 patients were stratified into the early enteroscopy group. The diagnostic yield, therapeutic yield, mortality, and rebleeding rate were similar between two groups. In multivariate conditional logistic regression analysis, there were no significant differences between two groups regarding the 30-day rebleeding rate (adjusted odds ratio [aOR], 1.43; 95% CI, 0.47-4.33), 90-day rebleeding rate (aOR, 1.18; 95% CI, 0.47-2.94), 30-day mortality rate (aOR, 1.29; 95% CI, 0.21-8.13), 90-day mortality rate (aOR, 1.94; 95% CI, 0.48-7.87), and 90-day bleeding-related mortality (aOR, 2.18; 95% CI, 0.24-19.52). The Kaplan-Meier survival curve analysis showed that the timing of DBE was not associated with the long-term rebleeding rate or mortality rate ( p = 0.57 and 0.83, respectively). CONCLUSION: The timing of enteroscopy did not influence the clinical outcomes, including the short-term mortality rate, short-term rebleeding rate, long-term mortality rate, and rebleeding rate, in patients with suspected overt small bowel bleeding.


Assuntos
Enteroscopia de Duplo Balão , Intestino Delgado , Humanos , Masculino , Idoso , Feminino , Estudos Retrospectivos , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/terapia , Colonoscopia
6.
BMC Gastroenterol ; 24(1): 10, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166722

RESUMO

BACKGROUND: Double-balloon enteroscopy (DBE) is a standard method for diagnosing and treating small bowel disease. However, DBE may yield false-negative results due to oversight or inexperience. We aim to develop a computer-aided diagnostic (CAD) system for the automatic detection and classification of small bowel abnormalities in DBE. DESIGN AND METHODS: A total of 5201 images were collected from Renmin Hospital of Wuhan University to construct a detection model for localizing lesions during DBE, and 3021 images were collected to construct a classification model for classifying lesions into four classes, protruding lesion, diverticulum, erosion & ulcer and angioectasia. The performance of the two models was evaluated using 1318 normal images and 915 abnormal images and 65 videos from independent patients and then compared with that of 8 endoscopists. The standard answer was the expert consensus. RESULTS: For the image test set, the detection model achieved a sensitivity of 92% (843/915) and an area under the curve (AUC) of 0.947, and the classification model achieved an accuracy of 86%. For the video test set, the accuracy of the system was significantly better than that of the endoscopists (85% vs. 77 ± 6%, p < 0.01). For the video test set, the proposed system was superior to novices and comparable to experts. CONCLUSIONS: We established a real-time CAD system for detecting and classifying small bowel lesions in DBE with favourable performance. ENDOANGEL-DBE has the potential to help endoscopists, especially novices, in clinical practice and may reduce the miss rate of small bowel lesions.


Assuntos
Aprendizado Profundo , Enteropatias , Humanos , Enteroscopia de Duplo Balão/métodos , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Enteropatias/diagnóstico por imagem , Abdome/patologia , Endoscopia Gastrointestinal/métodos , Estudos Retrospectivos
7.
J Pak Med Assoc ; 74(1): 158-160, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38219190

RESUMO

Crohn's disease (CD) affecting the jejunum and ileum is uncommon and its diagnosis can be challenging. This case report describes a 35 year old male patient who had been e xper iencing intermi ttent periu mbilica l pain , di arrho ea and fever for five years. Despite undergoing gastroscopy, co lo noscopy and capsule endoscopy; no s ignific ant abnormal ities were found. This case was se en at the Shenzhen Ho spital of Traditional Chinese Medi ci ne; Shenzhen, China. However, the pa tient u nder went a doubl e-balloon enteroscopy (DBE), which revealed multip le ulcers in the jejunum and ileum, leadin g to a confirmed diagnosis of CD. The patient was successfully treated with infliximab t o rel ieve sy mptoms. DBE can be par ticularly valuable in diagnosing CD in young patients with symptoms when conventional endoscopic techniques have been unsuccessfu l. This case highlights the impor tance of considering small bowel disease in patients wit h CD symptoms and the potential benefits of DBE in diagnosing such cases.


Assuntos
Doença de Crohn , Masculino , Humanos , Adulto , Doença de Crohn/complicações , Doença de Crohn/diagnóstico , Doença de Crohn/terapia , Jejuno/diagnóstico por imagem , Intestino Delgado , Enteroscopia de Duplo Balão/métodos , Íleo/diagnóstico por imagem
8.
Endoscopy ; 56(3): 174-181, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37949103

RESUMO

BACKGROUND: Device-assisted enteroscopy (DAE) has become a well-established diagnostic and therapeutic tool for the management of small-bowel pathology. We aimed to evaluate the performance measures for DAE across the UK against the quality benchmarks proposed by the European Society of Gastrointestinal Endoscopy (ESGE). METHODS: We retrospectively collected data on patient demographics and DAE performance measures from electronic endoscopy records of consecutive patients who underwent DAE for diagnostic and therapeutic purposes across 12 enteroscopy centers in the UK between January 2017 and December 2022. RESULTS: A total of 2005 DAE procedures were performed in 1663 patients (median age 60 years; 53% men). Almost all procedures (98.1%) were performed for appropriate indications. Double-balloon enteroscopy was used for most procedures (82.0%), followed by single-balloon enteroscopy (17.2%) and spiral enteroscopy (0.7%). The estimated depth of insertion was documented in 73.4% of procedures. The overall diagnostic yield was 70.0%. Therapeutic interventions were performed in 42.6% of procedures, with a success rate of 96.6%. Overall, 78.0% of detected lesions were marked with a tattoo. Patient comfort was significantly better with the use of deep sedation compared with conscious sedation (99.7% vs. 68.5%; P<0.001). Major adverse events occurred in only 0.6% of procedures. CONCLUSIONS: Performance measures for DAE in the UK meet the ESGE quality benchmarks, with high diagnostic and therapeutic yields, and a low incidence of major adverse events. However, there is room for improvement in optimizing sedation practices, standardizing the depth of insertion documentation, and adopting marking techniques to aid in the follow-up of detected lesions.


Assuntos
Enteropatias , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Enteropatias/diagnóstico , Enteropatias/terapia , Estudos Retrospectivos , Melhoria de Qualidade , Endoscopia Gastrointestinal/métodos , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Enteroscopia de Duplo Balão/métodos
13.
Artigo em Inglês | MEDLINE | ID: mdl-37652651

RESUMO

Device-assisted enteroscopy (DAE), balloon-assisted enteroscopy (BAE) in particular, has become a routine endoscopic procedure which has revolutionized our approach to small-bowel disease. Evidence demonstrating the efficacy and safety of BAE spans over 22-years of experience, making it an established pillar of minimally invasive care. The robust evidence for BAE's safety and efficacy has now been incorporated into international clinical guidelines, technical reviews, benchmarking performance measures and curricula. The more recently introduced motorized spiral enteroscopy (MSE) which had replaced the previous manual version, abruptly ended its 7-year stint in clinical practice, when it was withdrawn and recalled from the market by its manufacturing company in July 2023, due to several associated serious adverse events (including fatalities). This article, written by the original developer of double-balloon enteroscopy (DBE) and other recognized international experts and pioneers in this field, focuses mainly on the technical aspects, evolving indications, and equipment-related technological advances. Despite the very recent withdrawal of MSE from clinical practice, for completeness, this technology and its technique is still briefly covered here, albeit importantly, along with a short description of reported, associated, serious adverse events which have contributed to its withdrawal/recall from the market and clinical practice.


Assuntos
Enteropatias , Laparoscopia , Humanos , Intestino Delgado , Enteroscopia de Duplo Balão/efeitos adversos , Enteroscopia de Duplo Balão/métodos , Enteropatias/etiologia , Enteropatias/cirurgia
14.
Clin J Gastroenterol ; 16(6): 836-841, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37597132

RESUMO

A 53-year-old female patient, who had been treated for Crohn's disease for approximately 20 years, was admitted to our hospital with a chief complaint of persistent bloody stools. Colonoscopy, computed tomography, and magnetic resonance enterography revealed two stenoses of the ileum and multiple enlarged lymph nodes around the oral-side ileal stenosis. We accordingly performed transoral double-balloon enteroscopy and found ileal stenosis with an irregular mucosal surface. Based on pathological examination of the stenosis, adenocarcinoma of the small bowel was diagnosed for the oral-side stenosis. The stenosis on the anal side was benign. The two stenoses were resected simultaneously, and lymph node dissection was performed on the cancerous lesion. The diagnosis of the cancerous lesion was pStage IIIB, and immunohistochemical staining was positive for tumor protein 53. Patients with Crohn's disease are at a high risk of small bowel cancer, but no surveillance protocol has been established to date. We encountered a case of Crohn's disease in which radical surgery was possible, owing to preoperative pathological diagnosis, by using balloon-assisted enteroscopy. In this paper, we report a case that suggests the importance of performing balloon-assisted enteroscopy when small bowel stenosis is detected in patients with Crohn's disease.


Assuntos
Neoplasias Colorretais , Doença de Crohn , Neoplasias Duodenais , Obstrução Intestinal , Feminino , Humanos , Pessoa de Meia-Idade , Doença de Crohn/complicações , Doença de Crohn/diagnóstico , Doença de Crohn/patologia , Constrição Patológica/etiologia , Constrição Patológica/patologia , Enteroscopia de Duplo Balão , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/cirurgia , Intestino Delgado/patologia , Neoplasias Duodenais/patologia , Neoplasias Colorretais/patologia
17.
Acta Gastroenterol Belg ; 86(2): 269-275, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37428159

RESUMO

Background and study aims: Motorized spiral enteroscopy is proven to be effective in antegrade and retrograde enteroscopy. Nevertheless, little is known about its use in less common indications. The aim of this study was to identify new indications for the motorized spiral enteroscope. Methods: Monocentric retrospective analysis of 115 patients who underwent enteroscopy using PSF-1 motorized spiral enteroscope between January 2020 and December 2022. Results: A total of 115 patients underwent PSF-1 enteroscopy. 44 (38%) were antegrade procedures and 24 (21%) were retrograde procedures in patients with normal gastrointestinal anatomy with conventional enteroscopy indications. The remaining 47 (41%) patients underwent PSF-1 procedures for secondary less conventional indications: n=25 (22%) enteroscopy-assisted ERCP, n=8 (7%) endoscopy of the excluded stomach after Roux-en-Y gastric bypass, n=7 (6%) retrograde enteroscopy after previous incomplete conventional colonoscopy and n=7 (6%) antegrade panenteroscopy of the entire small bowel. In this group of secondary indications, technical success rate was significantly lower (72.5%) as compared to technical success rates in the conventional groups (98-100%, p<0.001 Chi-square). Minor adverse events occurred in 17/115 patients (15%), all treated conservatively (AGREE I and II). Conclusion: This study demonstrates the capabilities of PSF-1 motorized spiral enteroscope for secondary indications. PSF-1 is useful to complete colonoscopy in case of long redundant colon, to reach the excluded stomach after Roux-en-Y gastric bypass, to perform unidirectional pan-enteroscopy and to perform ERCP in patients with surgically altered anatomy. However, technical success rates are lower as compared to conventional antegrade and retrograde enteroscopy procedures, with only minor adverse events.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Endoscopia Gastrointestinal , Humanos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Estudos Retrospectivos , Intestino Delgado/cirurgia , Estômago , Enteroscopia de Duplo Balão
18.
BMC Gastroenterol ; 23(1): 247, 2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37475007

RESUMO

PURPOSE: To assess the efficacy of double-balloon endoscopy (DBE) for the detection of small-bowel strictures in Crohn's disease (CD). METHODS: This tertiary-referral hospital cohort study was conducted between January 2018 and May 2022. CD patients with symptoms of small-bowel stricture were enrolled sequentially. All of the patients were subjected to both computed tomography enterography (CTE) and DBE, and their symptoms of stricture were assessed using the Crohn's Disease Obstructive Score (CDOS). The diagnostic yield of DBE was compared to that of CTE, and the relationship between the DBE findings and CDOS was investigated. The factors influencing the DBE diagnosis were examined using Cox regression analysis. RESULTS: This study included 165 CD patients. The CDOS scores were higher in 95 patients and lower in 70 patients. DBE detected 92.7% (153/165) and CTE detected 85.5% (141/165) of the strictures. The DBE diagnostic yields were 94.7% (90/95) in the high CDOS patients and 91.4% (64/70) in the low CDOS patients (P = 0.13). Patients with a history of abdominal surgery and abscess had a lower diagnosis rate in the multivariate analysis. CONCLUSION: DBE has been demonstrated to be an efficient diagnostic method for detecting small bowel strictures in CD patients. Additionally, there was no difference in the diagnostic yields between patients with low and high obstructive scores.


Assuntos
Doença de Crohn , Obstrução Intestinal , Humanos , Doença de Crohn/complicações , Doença de Crohn/diagnóstico por imagem , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/etiologia , Intestino Delgado/diagnóstico por imagem , Estudos de Coortes , Obstrução Intestinal/diagnóstico por imagem , Obstrução Intestinal/etiologia , Endoscopia Gastrointestinal/métodos , Enteroscopia de Duplo Balão
20.
Surg Endosc ; 37(9): 6998-7011, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37349592

RESUMO

BACKGROUND: Motorized spiral enteroscopy (MSE) is a novel advance in small bowel examination that is characterized as fast with a deep insertion. The aim of this study was to elucidate the effectiveness and safety of MSE. METHODS: Relevant articles that were published before November 1, 2022 were identified by searching PubMed, EMBASE, Cochrane, and the Web of Science. The technical success rate (TSR), total (pan)-enteroscopy rate (TER), depth of maximum insertion (DMI), diagnostic yield, and adverse events were extracted and analyzed. Forest plots were graphed based on random effects models. RESULTS: A total of 876 patients from 8 studies were eligible for analysis. The pooled results of the TSR were 95.0% [95% confidence interval (CI) 91.0-98.0%, I2 = 78%, p < 0.01] and the pooled outcome of the TER was 43.1% (95% CI 24.7-62.5%, I2 = 95%, p < 0.01). The pooled results of the diagnostic and therapeutic yields were 77.2% (95% CI 69.0-84.5%, I2 = 84%, p < 0.01) and 49.0% (95% CI 38.0-60.1%, I2 = 89%, p < 0.01), respectively. The pooled estimates of adverse and severe adverse events were 17.2% (95% CI 11.9-23.2%, I2 = 75%, p < 0.01) and 0.7% (95% CI 0.0-2.1%, I2 = 37%, p = 0.13), respectively. CONCLUSION: MSE is a novel alternative approach for small bowel examination that can achieve high TER and diagnostic and therapeutic yields, and relatively low rates of severe adverse events. Head-to-head studies comparing MSE and other device-assisted enteroscopies are warranted.


Assuntos
Enteropatias , Laparoscopia , Humanos , Enteropatias/diagnóstico , Enteropatias/terapia , Endoscopia Gastrointestinal/efeitos adversos , Endoscopia Gastrointestinal/métodos , Intestino Delgado/diagnóstico por imagem , Enteroscopia de Duplo Balão/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...